CyberAir® CW and DX

Innovative CRACs and CRAHs for data centers

To Contact Form

The benchmark of flexibility and energy efficiency

CyberAir® CW and DX perimeter mounted cooling solutions control the conditions in the data center with the utmost precision, reliability, and energy efficiency. With 20 kW - 1,080 kW of cooling capacity, there is an air conditioner (CRAC) or air handler (CRAH) for almost any mission critical application. 

Data Center
Data Center
Our units are designed for highest requirements and maximum reliability
Small, medium & large rooms
Small, medium & large rooms
Precision air conditioning units for low to high heat loads
Hyperscale
Hyperscale
Optimized for air conditioning particularly large data centers
Touch display
Touch display
Touchscreen product interface
Free Cooling
Free Cooling
Maximum potential savings by using cool outside air

Product Overview

At a glance

Chilled Water (CW)

  • Largest capacity perimeter CW air handlers in the industry
  • Fewer units at higher capacity can significantly reduce capital cost and operating cost

Direct Expansion (DX)

  • DX Systems provided with highly efficient and reliable low noise scroll compressors
  • Optimized AWS/Free-cooling coils to closely match DX cooling capacities, increasing energy savings opportunities

Technical Data

  • 20 kW - 1080 kW
Benefits

Chilled Water

  • All EC Fans mounted in the cabinet meet full performance without having to be dropped into the raised floor.
  • Fewer units at higher capacity can significantly reduce capital cost and operating cost
  • Filter Plenums designed with increased surface area for filtration, lower pressure drop, and improved energy savings.

Direct Expansion

  • DX Systems provided with highly efficient and reliable low noise scroll compressors
  • Optimized AWS. Free-cooling capacities, increasing energy savings opportunities
  • Hot gas reheat- provides reheat using recycled compressor heat
  • Electronic expansion valves can be optimized to work over a wide range of conditions
Features

Chilled Water (CW)

  • Greater airflow than other solutions
  • 100% front access on all sizes
  • Multiple EC Fan options ( additional fans in same size cabinet )
  • 2x CW valves standard on CFD-510 and larger units ( option for 1 CW valve )
  • Dehumidification efficiently achieved through reduced air volume at maximum cooling
  • Standard and seismic floor stand available for all CW units
  • Filter plenums designed with increased surface area for filtrations, lower pressure drop, and improved energy savings.
  • Standard MRV 8 filters ( optional up to MERV 14 filters )
  • Made in the USA

Direct Expansion (DX)

  • DX systems provided with highly efficient and reliable low noise scroll compressors
  • Micro plate heat exchangers offer major improvements in heat transfer
  • Refrigeration-based dehumidification system effectively removes excess moisture
  • Snap actin/ full floating hot gas bypass system provides cooling capacity modulation and evaporator coil freeze protection
  • Multi stages of DX cooling to match load requirement
  • Made in the USA
Technical Data

 

High CapacityCRAC Dual Circuit DX SystemsCRAH Single & Dual CW Systems
kW20-10560-1,080
MBH70-360200-3.680
Tons6-3015-305
CFM900-15,0004,800-90,000

Technical data is subject to change without notice.

Details for CyberAir CW and DX

A Megawatt of Cooling Capacity

Highest Capacity CRAH in the Data Center Industry

The CyberAir CFD-1080 is the largest perimeter CRAH in the data center industry, offering up to 96,000 CFM/987 CFM/ft2 of air handling capability.  The CFD-1080 comfortably maximizes the cooling capacity per square foot, while allowing for ease of rigging and modularity. 

Ideal Applications

  • Hyperscale Data Centers
  • Colocation Data Centers
  • Cloud ISP
  • Enterprise Data Centers

Modular Deployment

The CyberAir 1080 data center CRAH is uniquely designed for modular deployment, with six separate sections (two fan, two coil, and two return filter plenum sections) delivered. Once fully assembled, the 1080 stands an impressive 13 feet tall.  The modular CRAH unit design allows for ease of rigging, solving one of the major challenges for data center infrastructure equipment deployment. 

  • Easier to handle & maneuver smaller sections
  • Added system redundancy
  • Split sections for access limitation

Features and Benefits

  • State-of-the-art Microprocessor with a range of BMS interface options
  • Dual 2-way modulating CW valves (600 WOG rated)
  • Multiple EC Fan configuration options
  • Dual Cooling Coil Circuits for added redundancy
  • Fewer units at higher capacity for reduced capital and operating costs
  • Dehumidification efficiently achieved through reduced air volume at maximum cooling
  • Seismic and non-seismic rated floor stands
  • 1" thick, hinged access panels6-piece unit construction for ease of transport and installation
STULZ E² Control and Monitoring

STULZ E² Controller ties everything together

  • Designed specifically for precision control of mission critical environments
  • Multiple I/O capabilities for all major components to optimize control for energy savings
  • Supports universal BMS interface for remote monitoring (address readable) and remote control (address writable)
  • Capable of network controllers in a workgroup (pLAN) to work as one (no BMS required)
  • Pre-engineered controls for economizers and adiabatic cooling

Benefits

  • Backlit LCD alphanumeric display for visual indication
  • Operated via 6-key menus, in five different modes
  • Unit functions for cooling, heating, humidifying and dehumidifying
  • Three levels of restricted entry into the configuration
  • Sensor inputs control inputs/outputs
  • Additional I/O sensors and alarms
  • Optionals UPS backup module 
  • Independent EC Fan and cooling control (CW valve or DX)
  • Cooling control sequence: return air temperature, humidity, supply air temperature, dew point
  • Fan control sequence: BMS, local/static pressure, and temperature based (supply or return air)
  • Capable of networking up to eight E2 Controllers with an independent LAN
  • Psychrometric control provided as a user configurable temperature and humidity (relative humidity) or dew point control

STULZ E² Controller communicates with BMS/BAS systems via the following protocols:

  • BACnet IP
  • BACnet over Ethernet
  • BACnet MS/TP
  • HTTP
  • SNMP V1, V2c
  • Modbus IP
  • Modbus RTU
Heat Rejection Options for STULZ DX Cooling

MicroChannel Condenser

Common Features for MicroChannel (SCS-MC) and Standard Condensers (SCS)

  • Direct-driven high performance axial fans
  • AC and EC Fan motor
  • Integrated control box with main disconnect and motor protection
  • Various fan speed control options based on refrigerant pressure
  • R-407c & R-410a rated
  • Low ambient temperature control options

Features Specific to MicroChannel Condenser (SCS-MC)

  • MicroChannel coil design provides better heat rejection with smaller footprint and improved SCOP
  • Lower weight than traditional design
  • Uses less refrigerant
  • Integrated receiver skid

Glycol System Pump Packages

  • Single and dual pump package with redundant pumps
  • Individually powered or powered from Drycooler

Glycol System Remote Drycooler

  • Direct-driven high performance axial fans
  • AC and EC Fan motor
  • Integrated control box with main disconnect and motor protection
  • Free cooling drycoolers are available for the entire product line

Contact

Find your individual STULZ contact

Product Downloads

  • File:
  • Language:
  • Date:

Related Products

Custom Indoor AHU

Learn More

CyberOne

Learn More

Compact CWE

Learn More

Contact

Do you have any questions? We will be happy to help! Please call us or follow our contact form.

To Contact Form
To top